The questions engineers ask first.
Forty-five answers on ordering, compatibility, certification, shipping and after-sales, plus company background and the five product lines. Confirmed figures are fixed in project documents.
45 answers across 11 groups.
Company & background
Who we supply, the engineering pedigree and where the products are used.
- Henzor Technology is a Changsha-based lithium battery exporter supplying residential storage systems, C&I storage cabinets, UPS backup batteries and mobility packs to distributors, installers, EPC contractors and fleet operators in dozens of overseas markets, supporting solar self-consumption, backup power and electrification projects.
- Our founder brings nearly 20 years in new energy covering lithium battery management systems, vehicle telematics terminals, big data cloud platforms, UPS lithium cabinets, residential energy storage and construction machinery batteries, personally holding over 30 patents and software copyrights.
Ordering & MOQ
How a programme starts, how minimum quantity is set, and what happens to samples.
- Minimum quantity is set per programme, because it follows the enclosure tooling, cell format and test batch rather than a fixed catalogue rule. Standard models start lower than custom frames. Confirmed figures are issued with the quotation: [[TXT-FAQ-MOQ]].
- Yes. Sample units are built on the same drawing and BMS configuration as the intended production version, so field results are comparable. Sample scheduling and cost are quoted separately from the batch price.
- Both. In OEM projects the specification and branding come from the customer; in ODM projects we propose the mechanical and electrical design against the application. Either way the drawing set is agreed in writing before production.
- Price is quoted as a unit cost with tooling, testing and documentation listed separately where they apply. Changes to cell format, enclosure or certification scope are re-quoted rather than absorbed.
- Terms are agreed per contract and confirmed on the proforma invoice. Typical structures combine a deposit with a balance against shipping documents. Exact terms are stated in the offer: [[TXT-FAQ-PAYMENT]].
- Standard workflow covers requirement review, feasibility assessment and quotation, technical specification sign-off, prototype build, joint type testing against agreed acceptance criteria, pilot batch validation, then release to mass production.
Technical & Compatibility
Voltage, BMS protocol, inverter and host-system integration.
- Yes, provided the host protocol and register table are available. We exchange register maps and alarm definitions before configuration, then verify on a bench with the actual host where possible.
- LFP is the default for stationary storage, UPS and off-road traction. NMC is used for light mobility where mass and volume matter more than cycle count. The choice is recorded in the specification with the reason.
- Series count and parallel modules can be adapted within the limits of the BMS platform and the enclosure. Each change is re-checked against thermal margin, breaker sizing and certification scope before it is quoted.
- Cell voltage, temperature, pack current, state of charge, state of health and active alarms are available over CAN or RS485. Mapping to a specific SCADA or EMS platform is agreed per project.
- Dimensioned drawings, mounting points, terminal locations and cable entry positions are issued for integration. Where the host system requires it, a 3D step file is provided under the project agreement.
Certification & Compliance
Test scope, documentation and market access requirements.
- Test scope is planned against the destination market and the product category. Cell and pack level reports, transport classification and system-level documentation are handled together, and the confirmed standard list for each model is issued with the quotation.
- Reports are issued to the programme they were tested for. Customers receive the report set covering their model and market, and the certificate holder is named on each document.
- Transport testing is planned per cell and pack configuration and is quoted with the programme. Air and sea shipping documents are prepared from the resulting test summary and MSDS.
- Yes. Where the customer holds the certificate, we provide the technical file, bill of materials and change notifications the certificate requires. Any design change that affects scope is reported before implementation.
- Labels are produced from the approved drawing and include the identifiers required by the destination market. Data fields for digital product passports are compiled as part of the document set.
- We supply CE documentation for European shipments where applicable, together with UN 38.3 test summaries and MSDS. Labelling and documentation can be aligned with evolving EU Battery Regulation requirements on request.
- Yes. We prepare complete certification documentation packages for CB scheme, CE marking, UKCA marking and local grid-code submission. For certificates not yet held, we coordinate accredited third-party laboratory testing and disclose estimated cost, sample quantity and timeline before any commitment.
Shipping & Lead Time
Dangerous goods handling, packaging, Incoterms and scheduling.
- Packs ship as dangerous goods under the classification stated in the transport report, with the packaging and marking that classification requires. Forwarders are selected for lithium experience rather than lowest rate.
- Lead time depends on whether the frame is standard or custom, and on the test scope. The schedule is confirmed at order review and stated on the proforma invoice: [[TXT-FAQ-LEADTIME]].
- EXW, FOB and CIF are the usual options, with DAP available where the destination can accept dangerous goods delivery. The chosen term and named place appear on the offer.
- Cabinets are packed on reinforced pallets with internal bracing, terminal protection and moisture control. Packing drawings are shared for approval before the first shipment.
- Multiple models can ship together when the dangerous goods declaration allows it. Consolidation is planned at order review so that documentation matches the actual container contents.
Warranty & After-Sales
Coverage terms, field issues and replacement process.
- Residential storage and UPS battery cabinets carry a standard 3-year warranty; extended terms can be written into the contract. Coverage is defined against capacity retention, workmanship and BMS function, and the conditions for the ordered model are issued with the quotation.
- The first step is data: BMS logs, operating conditions and photographs. Most cases are resolved by configuration or a module replacement. Physical returns are decided after the log review, not before.
- Spare modules and BMS boards can be supplied with the production order so that field service does not wait for a new build. Recommended spare quantity is stated in the offer.
- Take-back and recycling routes are agreed per market at the specification stage, and the responsible party is named in the document set.
- Installation and service training is available for integrators and distributors, delivered remotely or on site depending on the programme size.
Residential storage
Models, cycle life and backup switching for home systems.
- Our residential line covers 51.2V wall-mounted and mobile LiFePO4 battery boxes from 5.12 to 16 kWh, plus all-in-one units integrating battery, off-grid inverter and MPPT solar input in 5 kW and 11 kW classes.
- We specify 6,000 charge cycles under standard test conditions, commonly quoted at 70 percent retained capacity at 25 degrees Celsius. Real service life depends on depth of discharge, temperature profile, charging rate and maintenance practice.
- Yes. Our residential hybrid units transfer between grid-connected and off-grid operation within 10 milliseconds and exceed 98 percent peak conversion efficiency with pure sine wave output, protecting servers, medical equipment, lighting and well pumps from service interruption.
UPS & telecom backup
Voltage platforms, discharge rate and three-tier BMS protection.
- The Smart series covers 48V, 51.2V and 64V module platforms. Cabinets stack four to ten modules, giving system voltages from 192V to 640V and nominal energy from 12.8 kWh to 160.8 kWh; single-module units from 3.2 kWh serve smaller loads at 48V to 64V.
- High-rate configurations sustain 3C to 5C discharge for data centre and healthcare loads, holding stable output through the transfer window and engaging as soon as incoming mains fails.
- Protection runs concurrently at cell, module and system level, continuously monitoring voltage, current, temperature and insulation resistance, responding within milliseconds, isolating faults before thermal propagation, and escalating alarms automatically to your monitoring platform or building management system.
Off-road vehicles
Applications, lead-acid replacement and harsh-environment adaptation.
- We manufacture LiFePO4 lithium battery packs for golf carts, automated guided vehicles, scissor lifts, forklifts and pallet stackers, serving warehouse logistics, port and airport ground support, industrial material handling and resort fleet electrification programmes.
- Yes. We engineer drop-in lithium replacements matched to your existing battery tray, connector and voltage window, eliminating routine watering maintenance, shortening recharge time, enabling opportunity charging between shifts and removing dedicated battery room ventilation requirements.
- Yes. We adapt enclosure ingress rating, low-temperature self-heating strategy, vibration damping mounts, connector locking and anti-corrosion hardware to your actual site conditions, validating designs against jointly agreed mechanical and thermal acceptance criteria before release.
C&I storage cabinets
Site types, grid-to-island transfer and fire protection.
- Our cabinets serve peak shaving, demand charge management, diesel generator replacement, PV self-consumption optimization, data centre uninterruptible backup, industrial park microgrids, EV charging support, and off-grid or construction sites where supply is unstable or unavailable.
- Our hybrid and microgrid cabinets move between grid-connected and islanded operation in under 10 milliseconds, using integrated static transfer switch and automatic transfer equipment, so critical loads such as servers and process controls stay energized without restart.
- Cabinets integrate aerosol or perfluorohexanone fire suppression, module-level aerosol units, smoke and temperature detectors, IP55 ingress protection, and C3 corrosion-resistant coating with C4 and C5 available as options for coastal sites.
Two- & three-wheelers
Pack formats, battery swapping compatibility and humid-climate design.
- We produce lithium battery packs for electric two-wheelers and three-wheelers, including e-motorcycle, e-scooter and e-rickshaw configurations, sized for last-mile delivery, ride hailing and passenger transport duty cycles, in both fixed and swappable formats.
- Yes. We align mechanical interface, connector pinout, authentication logic and communication handshake with your battery swapping cabinet protocol, and deliver fleet telemetry through integrated BMS reporting for battery swapping operations and state of charge visibility.
- We specify sealing method, electronic potting compound, conformal coating, corrosion-resistant hardware and thermal management appropriate to tropical ambient temperatures and high humidity, validating long-term reliability through environmental cycling tests before approving customer samples.
Tell us the application. We reply with parameters, not a brochure.
Send the load profile, installation environment and target market. An engineer reviews the enquiry and answers within 48 hours of receiving complete requirements.
No obligation · NDA available on request